Parameter
ID |
Parameter Name |
Recommand value |
SRCHOCTRLSWITCH |
Current
HO CTRL Algorithm in Source Cell |
HOALGORITHM1 |
INTERCELLHYST |
Inter-cell
HO Hysteresis |
In
densely populated urban areas, the recommended value is 68; in the suburbs,
the recommended value is 72. |
MINOFFSET |
Min
Access Level Offset |
0 |
PBGTMARGIN |
PBGT
HO Threshold |
In
densely populated urban areas, the recommended value is 68; in the suburbs,
the recommended value is 72. |
BQMARGIN |
BQ
HO Margin |
69 |
ISCHAINNCELL |
Chain
Neighbor Cell |
NO |
INTELEVHOHYST |
Adjacent
Cell Inter-layer HO Hysteresis |
67 |
DRHOLEVRANGE |
Directed
Retry Handover Level Range |
72 |
CHAINNCELLTYPE |
Chain
Neighbour Cell Type |
QUICK_HO_NCELL_TYPE_A |
EDGEADJSTATTIME |
Edge
HO AdjCell Watch Time |
6 |
EDGEADJLASTTIME |
Edge
HO AdjCell Valid Time |
4 |
LEVSTAT |
Layer
HO Watch Time |
6 |
LEVLAST |
Layer
HO Valid Time |
4 |
PBGTSTAT |
PBGT
Watch Time |
6 |
PBGTLAST |
PBGT
Valid Time |
4 |
BETTERCELLSTATTIME |
Better
Cell HO Watch Time |
6 |
BETTERCELLLASTTIME |
Better
Cell HO Valid Time |
4 |
HOSTATICTIME |
Quick
Handover Static Time |
4 |
HOLASTTIME |
Quick
Handover Last Time |
3 |
HCSSTATTIME |
HCS
HO Watch Time |
3 |
HCSLASTTIME |
HCS
HO Valid Time |
2 |
BQSTATTIME |
BQ
HO Watch Time |
1 |
BQLASTTIME |
BQ
HO Valid Time |
1 |
TASTATTIME |
TA
HO Watch Time |
1 |
TALASTTIME |
TA
HO Valid Time |
1 |
ULBQSTATTIME |
UL
BQ HO Static Time |
1 |
ULBQLASTTIME |
UL
BQ HO Last Time |
1 |
IBCADYNCMEASURENCELLALLOWED |
IBCA
Dyn Measure Neighbour Cell Flag |
Set
this parameter to YES for the neighboring cell with co-channel interference
and the neighboring cell that may cause interference; set this parameter to
NO for other neighboring cells. |
IBCARXLEVOFFSET |
IBCA
RxLev Offset |
4 |
LOADHOPBGTMARGIN |
Load
HO PBGT Threshold |
0 |
NCELLPRI |
Neighboring
Cell Priority |
None |